Main factors affecting SNCR: Correct temperature window; Residence time in suitable temperature range; Uniform mixing; Molar ratio of reductant to NOx.
|
Technical key point: Selection of injection point; Design of ejector; Injection control strategy under different loads.
|
Technical solutions of Pyneo: In-depth basic research on chemical reaction of SNCR; Detailed CFD simulation to predict the combustion status of boiler; Specialized SNCR atomization, droplet mixing and reaction simulation; Series special nozzle design for SNCR; Pilot test verification of large-scale test bed.
|